Purpose: The purpose of this study is to evaluate the sensitivity and specificity of the detection of surgical sponges through the torso of non-morbidly obese and morbidly obese subjects using a radiofrequency mattress. Methods: A prospective, crossover, and observer blinded study design was used. Subjects served as their own controls. With the subject supine, 4 surgical sponges were sequentially placed on top of the subject's torso in locations approximating abdominal quadrants. In a subset of 118 subjects, the effectiveness of the RF mattress was compared to that of the RF wand. Results: 203 subjects were enrolled in the study, 61.1 % (n=129) of whom were morbidly obese (BMI =/> 40). 812 readings were taken with the RF mattress. In subjects with a body mass index (BMI) < 40, sensitivity and specificity of the mattress were 100%. In subjects with a BMI => 40, the sensitivity of the mattress was 96.9% and specificity was 100%. The mattress failed to detect 12 surgical sponges in 10 subjects with BMI ranging from 50.2 to 78.8. The results of the mattress were compared to those of RF wand in 118 subjects, including 85 who were morbidly obese. Sensitivity and specificity of the wand were 100% for non-morbidly obese and morbidly obese subjects. Conclusion: The sensitivity and specificity of RF mattress and wand technology are much higher than published reports of surgical counts or intraoperative radiographs for retained surgical items. The sensitivity of the RF wand is superior to the RF mattress for detection of sponges in morbidly obese subjects. Findings were consistent with a previous study finding the sensitivity of the wand to be 100%.

Author Details

Steelman, Victoria M., PhD, RN, CNOR, FAAN

Sigma Membership

Unknown

Type

Presentation

Format Type

Text-based Document

Study Design/Type

N/A

Research Approach

N/A

Keywords:

surgical sponge, patient safety, technology

Conference Name

23rd International Nursing Research Congress

Conference Host

Sigma Theta Tau International

Conference Location

Brisbane, Australia

Conference Year

2012

Rights Holder

All rights reserved by the author(s) and/or publisher(s) listed in this item record unless relinquished in whole or part by a rights notation or a Creative Commons License present in this item record.

All permission requests should be directed accordingly and not to the Sigma Repository.

All submitting authors or publishers have affirmed that when using material in their work where they do not own copyright, they have obtained permission of the copyright holder prior to submission and the rights holder has been acknowledged as necessary.

Acquisition

Proxy-submission

Share

COinS
 

Sensitivity of Radiofrequency Devices for Detection of Retained Surgical Sponges in Morbidly Obese Subjects

Brisbane, Australia

Purpose: The purpose of this study is to evaluate the sensitivity and specificity of the detection of surgical sponges through the torso of non-morbidly obese and morbidly obese subjects using a radiofrequency mattress. Methods: A prospective, crossover, and observer blinded study design was used. Subjects served as their own controls. With the subject supine, 4 surgical sponges were sequentially placed on top of the subject's torso in locations approximating abdominal quadrants. In a subset of 118 subjects, the effectiveness of the RF mattress was compared to that of the RF wand. Results: 203 subjects were enrolled in the study, 61.1 % (n=129) of whom were morbidly obese (BMI =/> 40). 812 readings were taken with the RF mattress. In subjects with a body mass index (BMI) < 40, sensitivity and specificity of the mattress were 100%. In subjects with a BMI => 40, the sensitivity of the mattress was 96.9% and specificity was 100%. The mattress failed to detect 12 surgical sponges in 10 subjects with BMI ranging from 50.2 to 78.8. The results of the mattress were compared to those of RF wand in 118 subjects, including 85 who were morbidly obese. Sensitivity and specificity of the wand were 100% for non-morbidly obese and morbidly obese subjects. Conclusion: The sensitivity and specificity of RF mattress and wand technology are much higher than published reports of surgical counts or intraoperative radiographs for retained surgical items. The sensitivity of the RF wand is superior to the RF mattress for detection of sponges in morbidly obese subjects. Findings were consistent with a previous study finding the sensitivity of the wand to be 100%.